额定电压1kV以下架空绝缘电缆
Insulated Aerial Cable with Rated Voltage up to 1kV
一、标准
本产品按GB12527-90或Q/SL109-2002标准组织制造。
Standards
The cable meets the standard requirements of GB12527-90 or Q/SL109-2002.
二、型号、名称、适用范围 Type, Designation and Applications
型号Type |
名称 Designation |
用途 Applications |
|
JKV-0.6/1 |
0.6/1kV铜芯聚氯乙烯绝缘架空电缆 0.6/1kV Cu conductor PVC insulated aerial cables |
架空固定敷设,外户线用等 For aerial fixed installation and laying outdoors. |
|
JKLV-0.6/1 |
0.6/1kV铝芯聚氯乙烯绝缘架空电缆 0.6/1kV Al conductor PVC insulated aerial cables |
架空固定敷设,外户线用等 For aerial fixed installation and laying outdoors. |
|
JKLGV-0.6/1 |
0.6/1kV钢芯铝绞聚氯乙烯绝缘架空电缆 0.6/1kV ACSR conductor PVC insulated aerial cables |
带承载架空固定敷设,外户线用等 For aerial fixed installation bearing external mechanical forces and laying outdoors. |
|
JKLHV-0.6/1 |
0.6/1kV铝合金芯聚氯乙烯绝缘架空电缆 0.6/1kV Al alloy conductor PVC insulated aerial cables |
带承载架空固定敷设,外户线用等 For aerial fixed installation bearing external mechanical forces and laying outdoors. |
|
JKY-0.6/1 |
0.6/1kV铜芯聚乙烯绝缘架空电缆 0.6/1kV Cu conductor PVC insulated aerial cables |
架空固定敷设,外户线用等 For aerial fixed installation and laying outdoors. |
|
JKLY-0.6/1 |
0.6/1kV铝芯聚乙烯绝缘架空电缆 0.6/1kV Al conductor PVC insulated aerial cables |
架空固定敷设,外户线用等,耐侯性好 For aerial fixed installation and laying outdoors. |
|
JKLGY-0.6/1 |
0.6/1kV钢芯铝绞聚乙烯绝缘架空电缆 0.6/1kV ACSR conductor PVC insulated aerial cables |
带承载架空固定敷设,外户线用等,耐侯性好 For aerial fixed installation bearing external mechanical forces and laying outdoors. |
|
JKLHY-0.6/1 |
0.6/1kV铝合金芯聚乙烯绝缘架空电缆 0.6/1kV Al alloy conductor PVC insulated aerial cables |
带承载架空固定敷设,外户线用等,耐侯性好 For aerial fixed installation bearing external mechanical forces and laying outdoors. |
|
JKYJ-0.6/1 |
0.6/1kV铜芯交联聚乙烯绝缘架空电缆 0.6/1kV Cu conductor XLPE insulated aerial cables |
架空固定敷设,外户线用等,可与树枝短时间接触 For aerial fixed installation and laying outdoors. |
|
JKLYJ-0.6/1 |
0.6/1kV铝芯交联聚乙烯绝缘架空电缆 0.6/1kV Al conductor XLPE insulated aerial cables |
架空固定敷设,外户线用等,可与树枝短时间接触 For aerial fixed installation and laying outdoors. |
|
JKLGYJ-0.6/1 |
0.6/1kV钢芯铝绞交联聚乙烯绝缘架空电缆 0.6/1kV ACSR conductor XLPE insulated aerial cables |
带承载架空固定敷设,外户线用等,可与树枝短时间接触 For aerial fixed installation bearing external mechanical forces and laying outdoors. |
|
JKLHYJ-0.6/1 |
0.6/1kV铝合金芯交联聚乙烯绝缘架空电缆 0.6/1kV Al alloy conductor XLPE insulated aerial cables |
带承载架空固定敷设,外户线用等,可与树枝短时间接触 For aerial fixed installation bearing external mechanical forces and laying outdoors. |
三 、规格 Specifications
型号 Type |
芯数 Number of cores |
标称截面(mm2) Nominal Cross-sectional Area |
|
JKV、JKLV、JKLGV、JKLHV、JKY、JKLY、JKLGY、JKLHY、JKYJ、JKLGYJ、JKLHYJ |
1 |
16~240 |
|
2、4 |
10~120 |
|
JKLV、JKLY、JKLYJ |
3+K |
10~120 |
四、结构示意图 Structure Drawing

五、使用特性
1、本产品使用的额定电压U0/U为0.6/1kV。
2、电缆导体的长期允许工作温度
——聚氯乙烯聚乙烯绝缘应不超过70℃。
——交联聚乙烯绝缘应不超过90℃。
3、安装条件
——电缆的敷设温度应不低于-20℃。
——电缆的允许弯曲半径
电缆外径D小于25mm者,应小于4D。
电缆外径D为25mm及以上者,应不小于6D。
——电缆架设时,应考虑电缆和树木保持一定距离,电缆运行时,只允许电缆和树木短时间接触。
Using properties
1 Rated voltage U0/U is 0.6/1kV.
2 Maximum continuous operating temperature requirements:
——For PE and PVC, 70℃.
——For XLPE, 90℃.
3 Installation requirements:
——Laying temperature shall not be less than -20℃.
——Minimum bending radius:
For that whose diameter is less than 25mm, shall be 4 times cable outer diameter.
For that whose diameter is equal to or greater than 25mm, shall be 6 times cable outer diameter.
——It should be considered to keep a certain distance between cables and trees during installation. Touch, between cables and trees, is allowable only for short time during operation.
六、技术参数 Technical Specifications